Also make sure your F vent closes properly along with RH2 if other areas are poorly adjusted.
To check it properly (and this often gets missed by some repairers), hold down RH3 to free the F vent and while doing that, press and release RH2 which opens and closes the F vent. Now check the closure of the F vent pad with the RH2 pad - both should close with equal pressure.
If this adjustment has been missed, you'll find you won't get much below low E.